Digital wire rope overload
The Turbocell magnetic digital overload sensor is manufactured and supplied as an economical product.
Unlike wire rope and under-cab models, this sensor does not measure and display the weight of the car, but its operation is based on the amount of displacement
caused by the bending of the wire rope springs or the contraction of the car floor, it detects the elevator overload and sends an overload command to the control panel.
The Turbocell magnetic overload measures the amount of spring contraction based on the measurement of the magnetic field of the magnet.
Installation on the cabin
In elevators with towing springs:
1) First install the metal base on the spring screw of the towing spring.
2) Install the controller on the base using two wing screws.
3) Place the magnet under the sensor. (If the magnetic field does not change, reverse the magnet.)
4) Place the magnet in the best spot by moving the sensor distance.
.
Under-cab installation
2) Install the controller on the base using two wing screws.
3) Place the magnet under the cabin floor and under the sensor.
4) Place the magnet in the best spot by moving the sensor distance.